Vapour compression refrigeration system essay

The motor is hermetic and is designed to operate, and be cooled by, the refrigerant being compressed. Procedure In order to estimate the effect of the water flow in the condenser on the refrigeration process, in Section A the flow rate of the water was altered, while keeping other parameters constant.

That is, the system and the surroundings are returned to their initial states at the end of the reverse process.

Of Mechanical Engineering, Deptt.

Vapour Absorbtion Refrigeration

During the compression along Vapour compression refrigeration system essay pressure rise,temperature if air also increases. No work can be completed without the encouragement of family members and friends.

The disadvantage of this type of compressor is a failure of the shaft seals, leading to loss of refrigerant. The actual vapor-compression refrigeration cycle investigated is presented in Figure by temperature entropy T-s diagram.

The optimal flow rate is determined for condenser and evaporator. However, an early approach to the manufacturer for comprehensive details of the system characteristics received a negative response.

Refrigeration and Air Conditioning Essay

Schematic representation and T-s diagram for ideal vapor compression cycle Cengel, Between points 5 and 1, the cold and partially vaporized refrigerant travels through the coil or tubes in the evaporator where it is totally vaporized by the warm air from the space being refrigerated that a fan circulates across the coil or tubes in the evaporator.

This worm compressed air is force into heat exchanger, which cooled the air at constant pressure. The lost work produced in the expansion value is represented by the area t-s-r-u-t, and it can be obtained from: At the same time, readings for the refrigerant flow rate had to be taken on the unit itself and typed into the mimic diagram of the programme.

For a vapor compression cycle, COP is defined as the amount of cooling produced per unit work supplied. To complete the refrigeration cyclethe refrigerant vapor from the evaporator is again a saturated vapor and is routed back into the compressor.

Between point 3 and point 4, the vapor travels through the remainder of the condenser and is condensed into a saturated liquid. During the heating process, the vapour refrigerant is driven off by the solution and enters into the condenser where it is liquefied.

Between points 4 and 5, the saturated liquid refrigerant passes through the expansion valve and undergoes an abrupt decrease of pressure.

Refrigeration Experiment Essay Sample

In this cycle vapour is compressed, then condensed to a liquid, following which the pressure so that fluid can evaporate at low pressure.Vapor Compression Refrigeration System Vapor compression refrigeration system is the most common refrigeration system used nowadays.

In vapor compression refrigeration cycle (VCRC), there are four major thermal process take place which is expansion, evaporation, compression and condensation.

Refrigeration Experiment Essay Sample The laboratory session for refrigeration system was performed in order to investigate the main concepts of the vapour-compression refrigeration cycle.

Simple refrigeration system studied in the laboratory is a prototype for a variety of engineering applications utilized in industrial, domestic and scientific purposes.

Vapor-compression refrigeration or vapor-compression refrigeration system (VCRS), in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air-conditioning of buildings and automobiles.

It is also used in domestic and commercial refrigerators, large-scale warehouses for chilled or frozen storage of foods and meats, refrigerated. The compression process increases the temperature of refrigerant from lower limit T2 to the upper limit Tl.

Work is supplied to the system and after compression, the vapour is wet or saturated but not superheated. Process The refrigerant in the form of vapour enters the condenser at state 2 and heat is rejected at constant pressure and temperature.

The vapour absorption system uses heat energy, instead of mechanical energy as in vapour compression system, in order to change the condition of the refrigerant required for the operation of the refrigeration cycle. In this system, the compressor is replaced by an absorber, a pump, a generator, and a pressure reducing valve.

This complete papers [ ]. The first working vapour-compression refrigeration system in the world which operated on a closed cycle as to run continuously wasn’t built until by American expatriate to Great Britain Jacob Perkins.

Vapour Compression Refrigeration System

Until this point, ice houses or natural sources of cold (snow, cold lakes) were used to provide cool storage for most of the year.

Download
Vapour compression refrigeration system essay
Rated 4/5 based on 62 review